The recording window is anchored to OP25 control-channel timestamps, but
the buffered audio lags those by roughly 1.5s. Trim logs across seven
calls measured the offset at 0.84-1.62s, consistently present.
At a 1.0s pad a short call closed its window before the voice arrived:
a 0.97s control-channel call closed at T+1.97 while voice started around
T+1.5, capturing ~0.4s of speech and cutting mid-word. Confirmed by a
0.57s file whose final 0.10s measured -12.2dB against its own -18.2dB
average - clipped speech, not a tail - and by two short calls that
logged no trim at all because no trailing silence remained.
Being generous is free here: trim_silence already strips trailing
silence back to the guard margin before upload, so long calls are
unaffected while short ones gain the window they need. Over-capture
costs nothing; under-capture loses words permanently.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Measured six recordings off a live P25 node and found two independent
defects causing lost audio at the end of calls:
- stop_recording() sliced the ring buffer immediately, so if the MP3
muxer had not yet delivered the tail the file was silently short.
Now waits (bounded, 2s) until buffered audio covers the end epoch.
- TGID-change closes used the new grant's epoch as the end with no pad
at all, guaranteeing truncation on every split. Tail pad is now a
setting, default raised 0.5s -> 1.0s.
The ring buffer also capped maximum call length: a call longer than the
buffer had its front silently clamped. The ring now serves the pre-roll
only, with a per-call accumulator for the rest, bounded at 4.8MB.
Clamping is loudly warned rather than silent.
Uploads averaged 63% silence, which inflates STT cost and is a known
Whisper hallucination trigger. Leading/trailing silence is now trimmed
conservatively (-40dB, 0.25s guard, internal pauses untouched).
started_at/ended_at still describe the call; new audio_* fields carry
the trimmed audio bounds so playback can map back to wall clock.
All-silence recordings are skipped and logged instead of uploaded.
Also: log measured control-channel idle on idle-timeout closes so
CALL_IDLE_TIMEOUT can be tuned from data, and quiet the httpx logger
which emitted ~170k lines/day of poll noise.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>